GE Panametrics GM868-1-3EX-10414-22-0

Item Part No&Description Specifications
1.10 GM868-1-3EX-10414-22-0 GM868 General Purpose Flowmeter with RS232 digital port;
capable of measuring flow velocity, actual or standard volumetric
flowrate Note- Determination of standard volumetric flow requires
pressure and temperature inputs (See section H)
    1-Single channel 
    3-12 to 28 VDC operating voltage 
    EX-Aluminum IP66 & Flameproof/Explosionproof enclosure.  Suitable
for ATEX IIC environments. 
    1-Two isolated 4 to 20 mA outputs (Standard) 
    0-None 
    4-ModBus digital output only 
    1-Two isolated configurable 4 to 20 mA inputs for pressure or
temperature (Internal 24 VDC supply)
    4-100 kHz transducer operating frequency 
    22-ATEX II 2 G Ex d IIC T6 Gb (Ta = -50C to 60C). Requires enclosure
option D = EX.
    0-None 
     /TD>
1.20 223-012 Surge protector for 4-20mA analog output or input
         
2.10 GF868-1-2EX-20A14-2-0-0 GF868 Flare Gas Flowmeter with RS232 digital port; 2 Analog
outputs, capable of determining flow velocity, actual or standard
volumetric flowrate, average molecular weight and mass flow
    1-Single channel
    2-220 to 240 VAC operating voltage 
    EX-Aluminum IP66 & Flameproof/Explosionproof enclosure.  Suitable
for ATEX IIC environments. 
    2-Four isolated 4 to 20 mA outputs
    0-None 
    A-HART communication only 
    1-Two isolated configurable 4 to 20 mA inputs for pressure or
temperature (Internal 24 VDC supply)
    4-100 kHz transducer operating frequency
    22-ATEX II 2 G Ex d IIC T6 Gb (Ta = -50C to 60C). Requires enclosure
option D = EX.
    0-Standard Software
    0-None
     
2.20 223-012 Surge protector for 4-20mA analog output or input
         
3 GC868-1-3EX-10415-0-S-0 GC868 Clamp On Gas Flowmeter with RS232 digital port; capable
of measuring flow velocity, actual or standard volumetric flowrate
with NX19 'coarse method' supercompressibility compensation -
steam and mass flow 
    1-Single channel 
    3-12 to 28 VDC operating voltage 
    EX-Aluminum IP66 & Flameproof/Explosionproof enclosure.  Suitable
for ATEX IIC environments. 
    1-Two isolated 4 to 20 mA outputs (Standard) 
    0-None 
    4-ModBus digital output only 
    1-Two isolated configurable 4 to 20 mA inputs for pressure or
temperature (Internal 24 VDC supply)
    5-200 kHz transducer operating frequency 
    0-None / General Purpose, NEMA 4X & IP66. Requires enclosure
option D = 1 or 2.
    S-  Stainless steel engraved tag (single line of data)