Item |
Part No&Description |
Specifications |
1.10 |
GM868-1-3EX-10414-22-0 |
GM868 General Purpose Flowmeter with RS232 digital port; capable of measuring flow velocity, actual or standard volumetric flowrate Note- Determination of standard volumetric flow requires pressure and temperature inputs (See section H) |
|
|
1-Single channel |
|
|
3-12 to 28 VDC operating voltage |
|
|
EX-Aluminum IP66 & Flameproof/Explosionproof enclosure. Suitable for ATEX IIC environments. |
|
|
1-Two isolated 4 to 20 mA outputs (Standard) |
|
|
0-None |
|
|
4-ModBus digital output only |
|
|
1-Two isolated configurable 4 to 20 mA inputs for pressure or temperature (Internal 24 VDC supply) |
|
|
4-100 kHz transducer operating frequency |
|
|
22-ATEX II 2 G Ex d IIC T6 Gb (Ta = -50C to 60C). Requires enclosure option D = EX. |
|
|
0-None |
|
|
/TD> |
1.20 |
223-012 |
Surge protector for 4-20mA analog output or input |
|
|
|
|
|
2.10 |
GF868-1-2EX-20A14-2-0-0 |
GF868 Flare Gas Flowmeter with RS232 digital port; 2 Analog outputs, capable of determining flow velocity, actual or standard volumetric flowrate, average molecular weight and mass flow |
|
|
1-Single channel |
|
|
2-220 to 240 VAC operating voltage |
|
|
EX-Aluminum IP66 & Flameproof/Explosionproof enclosure. Suitable for ATEX IIC environments. |
|
|
2-Four isolated 4 to 20 mA outputs |
|
|
0-None |
|
|
A-HART communication only |
|
|
1-Two isolated configurable 4 to 20 mA inputs for pressure or temperature (Internal 24 VDC supply) |
|
|
4-100 kHz transducer operating frequency |
|
|
22-ATEX II 2 G Ex d IIC T6 Gb (Ta = -50C to 60C). Requires enclosure option D = EX. |
|
|
0-Standard Software |
|
|
0-None |
|
|
|
2.20 |
223-012 |
Surge protector for 4-20mA analog output or input |
|
|
|
|
|
3 |
GC868-1-3EX-10415-0-S-0 |
GC868 Clamp On Gas Flowmeter with RS232 digital port; capable of measuring flow velocity, actual or standard volumetric flowrate with NX19 'coarse method' supercompressibility compensation - steam and mass flow |
|
|
1-Single channel |
|
|
3-12 to 28 VDC operating voltage |
|
|
EX-Aluminum IP66 & Flameproof/Explosionproof enclosure. Suitable for ATEX IIC environments. |
|
|
1-Two isolated 4 to 20 mA outputs (Standard) |
|
|
0-None |
|
|
4-ModBus digital output only |
|
|
1-Two isolated configurable 4 to 20 mA inputs for pressure or temperature (Internal 24 VDC supply) |
|
|
5-200 kHz transducer operating frequency |
|
|
0-None / General Purpose, NEMA 4X & IP66. Requires enclosure option D = 1 or 2. |
|
|
S- Stainless steel engraved tag (single line of data) |
|
|
|
|
|
|